MAX-600Z: total control and professional sound for multi-zone installations
The MAX-600Z is a 600 W RMS multi-zone PA amplifier, designed for demanding installations that require individual zone control, high power, and maximum reliability. It features Class D technology and a SMPS switched-mode power supply, ensuring energy efficiency and reduced heat generation. It also includes a complete Bluetooth/USB/FM player and can be controlled via a wall-mounted remote panel or ZONEMIC-6 zone microphone.
Technical advantages of the MAX-600Z for professionals
The MAX-600Z stands out for its operational versatility and advanced features:
- 5 independent output zones with volume selector and off option.
- Flexible inputs: 5 mic/line channels with phantom power, 3 auxiliary RCA, and emergency input.
- Priority control via chime tones, contact closures, attenuator priority, and emergency input.
- Fanless silent cooling, ideal for environments requiring quiet and maintenance-free operation.
Why choose the MAX-600Z multi-zone PA amplifier?
This device is ideal for professional installers seeking reliability and control in public address systems for segmented spaces:
- Configurable speaker outputs at 100 V, 70 V or 4 Ω, and multi-zone output option up to 240 W per zone.
- Built-in protections against overcurrent, overload, overheating, and short circuits.
- Precise controls: mix, gain, tone, priority level, and VOX with 7 adjustable levels.
- Compact design (2U, 19'' rack), easy to integrate into fixed installation systems.
FEATURES: | Class D PA amplifier and SMPS switch-mode power supply. Bluetooth/USB/FM player. ZONEMIC-6 zone microphone input. Input for remote wall panel. Microphone input with mix, gain and priority level control. Ringtone generator (Chime). 3 auxiliary inputs. Emergency input and mute for connection to alarm and evacuation systems. 24 V attenuator priority. 3rd wire output (100 V) with attenuator priority. Tone controls. 100 V, 70 V and 4 Ω outputs. 5 outputs zones with volume control and Off. |
POWER: | 600 W RMS |
RESPONSE: | 45-22,000 Hz (-10 dB) |
DISTORTION: | THD+N: <0.5% at 1 kHz |
S/N RATIO: | Mic >73 dB, Line >80 dB, Aux >84 dB |
PROTECTIONS: | Soft start, over-current, overload, over-temperature and short circuit |
INPUTS: | Zone microphone ZONEMIC-6, RJ45, up to 200 m cable length Remote wall panel, RJ45, 2 x 250 mV RMS (-12 dBV) CH 1, 2, 3, 4 and 5 micro/line balanced with 48V phantom power. Combo (XLR + 6.3 mm) and euroblock. Ring tones for contact closure Mic signal level: 5'2 mV RMS (-45 dBV) / 600 Ω Line signal level: 220 mV RMS (-13 dBV) / 100k Ω 3 x AUX. 2 x RCA connector. Signal level 270 mV RMS (-11 dBV) / 47.000 Ω 1 x emergency. Euroblock connector. Signal level: line 326 mV RMS (-10 dBV) or line 100 V Mute (Emergency Priority) by closing contacts. Euroblock connector 1 Amp-in. RCA connector. Signal level 1'2 V RMS (+ 1'5 dBV) |
OUTPUTS: | 1 REC. 2 x RCA connector. Signal level 316 mV RMS (-10 dBV). Pre-master. 1 Pre-out. RCA connector. Signal level 1.2 mV RMS (+1.5 dBV) 100 V, 70 V or 4 Ω speaker output, or 5 zones of 100 V loudspeakers with 7-position volume selector and OFF (max. 240 W per zone). Euroblock connector 1 Attenuator priority, 24 V 100 mA and contact closure. Euroblock connector 1 3rd priority wire for attenuators (100 V) |
IMPEDANCE: | 4 Ω and 100 V (16.7 Ω) and 70 V (8.17 Ω) line, euroblock |
FUNCTIONS: | Priority of entries (in order of attenuation): · 100V Emergency Input with selectable signal level (VOX) · Mute by closing contacts · ZONEMIC-6 zone microphone · Remote wall panel · Microphone 1 with selectable signal level (VOX) · Channels 2 | 3 | 4 | 5 with selectable signal level shared CH 2-3-4-5 (VOX) · Auxiliary Inputs | Player Light ignition ring in volume control, AUX input indicators, zones and player. Indicator lights for power, signal, clip, priority activation and protection Induction cooling, fanless. Silent and maintenance free |
PLAYER: | Bluetooth/USB/FM player for ambient music playback 5.3 Bluetooth Autoplay, starts playback automatically when switched on Memory of the last selected mode Playback mode memory (random, repeat). |
CONTROLS: | Microphone volume Master volume Auxiliary input selector or player Zones with power on and 7 volume positions Tone: bass and treble (±10 dB 100 Hz and 10k Hz). Mic/line/phantom selector, ring tones and priority Ringing tone level (chime) Priority activation signal level (VOX) |
TEMPERATURE: | Operation: -10º ~ 40ºC Storage: -20º ~ 60ºC |
MAXIMUM HUMIDITY: | 90% |
POWER SUPPLY: | 230/115 V AC 50-60Hz Power consumption: 750 W AC fuse 230 V 8 A / 115 V 16 A |
DIMENSIONS: | 430 x 89 x 320 mm depth. 2 U 19” rack |
WEIGHT: | 12.1 kg |
ACCESSORIES: | FM antenna Bluetooth antenna Power cable Rack mounts |